Sequence of Operation
System Sequence of Events
Objective Equipment List
Apex Technical Support 800-272-7937
Option 1
Page 4-13
¨ Apex Destiny 6100 control panel, rev. 8.05 or greater
¨ Apex RK36 or RKLCD keypad
¨ Sure Action 4000/8000 Series Pulsor Sensors
¨ Sure Action Processor, SU-313
¨ X-10 PRO “On” and “Off” Only Wall Switch, XPS3
¨ X-10 PRO Power Line Interface Module, PSC05
To automatically
activate the bathroom
exhaust fan when
someone steps into
the shower or in front
of the commode.
When the stress sensors beneath the floor in front of the commode or shower senses activity,
the bathroom fan will automatically turn on for fifteen (15) minutes and then turn off.
1) The weight of a person on the floor in front of the commode or shower will trip a silent
zone (Zone 1) on the panel via the Sure Action Pulsor/Processor.
2) The panel will send an X-10 command to turn on the exhaust fan (Control Channel 33
assigned to an X-10 address A1) and will automatically count down for fifteen (15)
minutes before turning off the fan.
- Application Note -
End User Convenience
- Bathroom Courtesy Fan -
Sure Action Pulsor Sensor