Destiny apex 6100 Bedienungsanleitung Seite 47

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 77
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 46
Required Programming
Application Diagram
Doorbell Interface with Remote Two-Way Voice
Location Value Function
9940 01 Zone type = 011, Option 1 = 064, Option 2 = 033,
Hardware device = 000, Input = 01
9940 02 Zone type = 011, Option 1 = 016, Option 2 = 001,
Hardware device = 000, Input = 02
0398 134 Enable auxiliary zone type to dial phone number 2 and activate 2-way
9920 001 083(Guest), 306(At), 077(Front), 060(Door)
0901 002 Link zone 1 to control channel 2
0902 001 Zone opening sends an ON command to channel 2
4097 001 Enable control channel 1
4119 008 Assign control channel 1 to the on-board relay
0203 001 Activate the on-board relay only while 2-way voice is active
4121 011 Enable control channel 2 with countdown in seconds
4124 160 Disable channel 2 when system is disarmed, or armed to home/night
4125 003 Give channel 2 a 3-second countdown
4143 001 Assign channel 2 to auxiliary output pin #1
0464 009 Two-way voice options = 0 exits to keypad mode/one digit access
07/99