Required Programming
Intruder Audible and Visual Warning
Location Value Function
4865 001 Enable control channel 33
4867 001 Activate chain channel
4886 001 Chain channel 1
4889 011 Enable control channel 34 with automatic turn-off
4892 160 Filter - disable when disarmed and also when armed to home or night
4893 002 On units (seconds)
4911 001 Auxiliary output 1
4913 011 Enable control channel 35 with automatic turn-off
4916 160 Filter - disable when disarmed and also when armed to home or night
4917 003 On units (seconds)
4935 008 Auxiliary output 8
4937 013 Enable control channel 36 with automatic turn-off and timer restart
4940 008 Filter - disable when light(sunrise)
4941 005 On units (minutes)
4958 176 X-10 output signal = H1
5441 034 Channel activation 1, chain channel 1
5442 035 Channel activation 2, chain channel 1
5443 036 Channel activation 3, chain channel 1
5570 005 X-10 input 1 signal = M6
5572 024 On function = output control assignment 1
5576 009 X-10 input 2 signal = M10
5578 022 On function = sunset
5579 021 Off function = sunrise
4021 033 Output control assignment 1 = channel 33
4022 005 Output control assignment 1 options = turn channel on and suppress speech
9940 16 Zone type = 011, Option 1 = 064, Option 2 = 033, Hardware device = 000, Input = 16
9940 17 Zone type = 015, Option 1 = 000, Option 2 = 001, Hardware device = 020, Input = 1
9940 18 Zone type = 015, Option 1 = 000, Option 2 = 001, Hardware device = 020, Input = 2
9920 016 371(Warning), 358(Protected), 029(Area), 096(Leave Immediately)
Application Diagram