Required Programming
Location Value Function
4865 097 Enable control channel 33 with off and on time-of-day schedule
4866 127 Enable days of week operation (7 days selected)
4887 008 Auxiliary output 8
9992 33 On time = 2100(9 PM), off time = 0700(7 AM)
4889 001 Enable control channel 34
4911 001 Auxiliary output 1
4913 013 Enable control channel 35 with automatic turn-off and countdown restart
4917 005 On units (minutes)
4934 096 X-10 output signal = A1
0901 009 Zone – control channel link option (open = on, closed = off)
0902 034 Zone – control channel link channel (zone 1, channel 34)
0917 001 Zone – control channel link option (open = on)
0918 035 Zone – control channel link channel (zone 2, channel 35)
9940 01 Zone type = 000, Option 1 = 080, Option 2 = 033, Hardware device = 000, Input = 01
9940 02 Zone type = 011, Option 1 = 000, Option 2 = 001, Hardware device = 000, Input = 02
9920 001 109(Motion), 056(Detected)
Application Diagram
Motion Activated Light During Specified Time