Disarm: Active when the panel is disarmed. The output is restored when the panel is armed.
Access Code Entered: Output is activated when an access code is entered. There is
not an event that restores the output , it is recommended to only use this trigger with
channels programmed to automatically turn off.
Alert: Activates the specified output during all alarm activations. The output is
restored after the alert status is cleared from the keypad.
Loss of Phone Line: Activates the specified output when a loss of phone line is
detected. The output is restored when the phone line is restored.
Duress Disarm: Activates the specified output when a duress disarm occurs. There
is not an event that restores the output, it is recommended to only use this trigger
with channels programmed to automatically turn off.
Duress When Not Armed: Activates the specified output when a duress occurs when
the system is not armed. There is not an event that restores the output, it is
recommended to only use this trigger with channels programmed to automatically
turn off.
AC Fail: Activates the specified output when power loss occurs. The output is
restored when power is restored.
Two-Way Voice: Activates the specified output when two-way voice is active. The
output is restored when two-way voice ends.
Smoke Reset: Activates the specified output when smoke reset occurs. The output is
restored when smoke reset ends.
Speech Activation: Activates the specified output when the system is speaking. The
output is restored when the system stops speaking.
Ring Detect: Activates the specified output when the phone rings. The output is
restored when the phone stops ringing.
House Phone Off Hook: Activates the specified output when a house phone is off
hook. The output is restored when the phone is hung up.
Communicator Fail: Activates the specified output when the panel in unable to
communicate with a central station receiver. The output is restored after the next
valid transmission.
Trigger a Relay: Activates the specified output when triggered by a portable
transmitter or keypad button. The output is restored by toggling the button used for
activation.
Two Way Callback: Central stations that do not support two-way voice after a communicator transmission
may require two-way callback. With this option enabled (System Option Group 3)
the control panel will wait a programmed period of time (0461) after a digital
communication for the central station to call. Two-way voice is not permitted in a
UL installation.