Destiny 4100 Spezifikationen Seite 14

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 64
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 13
14
Auxiliary Relay: A programmable relay is available on the "RC", "RNC" , and "RNO" terminals. Use "RC"
for relay common, "RNC" for relay normally closed or "RNO" for relay normally open.
Battery Leads: Connect the red lead to the + battery terminal and the black lead to the - battery
terminal. The battery is tested every 180 seconds to ensure it is present and
charged. A low battery condition can be indicated at the keypad and/or
communicated to the central station.
Auxiliary Outputs: An auxiliary output wire harness is supplied for J5. There are 4 programmable
output pins and 2 power pins. Pins 1-4 will provide a ground path when activated.
Pins 5 & 6 supply +12V DC. Do not exceed 100 mA per pin or 200mA total. These
outputs are intended to drive relays with a coil impedance of 500W or greater or any
other device requiring 100 mA or less. The outputs are not intended to power
devices without the use of a relay. It is acceptable to power an LED when a 1KW to
4.7KW, current limiting resistor is wired in series. Auxilary outputs should be used
to control devices "inside" the cabinet so as to provide maximun electrical
protection. Use of Auxiliary Outputs is not permitted in a UL installation. See
System Triggers section for programming information.
Microphone Input: A microphone wire harness is supplied at J2. Consult the Specifications section to
determine compatible microphones. It is recommended to only wire 1 microphone
to each of the 3 input channels allowing a central station to have full control of each
microphone during a two-way session. Use of two-way voice is not permitted in a
UL installation.
Power Switch: Located in the center of the control board is a black slide switch which controls all
power (including the battery) to the system. Right = ON; Left = OFF.
Siren Adjustment: The potentiometer marked "Siren" on the left side of the control board controls the
volume level of any system generated speech and the key depression feedback
beeps. Using a small screwdriver, turn the potentiometer to obtain the desired
volume. Clockwise increases volume. This adjustment will not the affect alarm
notification volume from the speaker during an activation.
Program Switch: Located in the upper right corner of the control board, this switch is used to return
the system to various defaults. Holding the button down and releasing after a
specific number of "beeps" will activate different system functions:
beeps Action
1 Return user code 1 to default: 1,2,3,4
3 Enter direct connect mode (Same as 9952 in program mode)
5 Return service (program) code default: 9,1,7,3
10 Default panel
other Three error beeps: no programming is affected.
Hardwire Inputs: There are 8 hardwire inputs on the control panel. Through programming, each input
can be wired in one of three ways: with a 4.7KW end-of-line resistor (EOLR), without
an EOLR, or with resistor supervision.
Two-Way Adjustment: The potentiometer marked "2-WAY VOL" controls the volume level of voice over the
phone line to the inside speaker during two-way communication or paging. Using a
small screwdriver, turn the potentiometer to obtain the desired volume. Clockwise
increases volume. This adjustment will not the affect alarm notification volume
from the speaker during an activation. Use of two-way voice is not permitted in a
UL installation.
Upload / Download LED: At the top right of the board is a yellow LED labeled "U/D" which is illuminated when